What regular inspections are required for hyperbolic mixers


Release Time:

Oct 16,2023

1. After a long period of inactivity, the insulation of the motor should be checked before restarting the hyperbolic mixer. At the same time, it is necessary to prevent sediment from accumulating for a long time, which may cause difficulty in starting and damage the motor and impeller.
2. Regularly inspect the locking nuts and connecting bolts of the mixing shaft of the hyperbolic mixer for looseness.
3. Regularly check the oscillation of the mixing shaft and promptly remove any entanglements on the impeller and shaft.
4. Regularly check the transport components for abnormal sound and temperature rise.
5. Regularly check for any abnormal changes in the current of the hyperbolic mixer.